Description
- Sensing Element: Heated Tin Oxide
- Sensor Life: 2000 hours
- Refrigerants: Detects all refrigerants (HFC, CFC, HCFC, and blends)
- Sensitivity Levels:
- HIGH: 0.15 oz/yr (4 g/yr)
- MEDIUM: 0.25 oz/yr (7 g/yr)
- LOW: 0.50 oz/yr (14 g/yr)
- Response Time: less than 1 second
- Battery: 2 “C” Alkaline 6000 mAh batteries
- Operating Temperature Range: 0F to 120F
- Probe:
- Intelligent tip, with environment sensing element to eliminate the potential of false alarms
- Flexible 15.5 inch probe length for difficult to reach locations
- Display:
- Six vertical LED’s enabled selectively (red, yellow or green) to display the following information to the user such as:
- The relative signal level of the detected leak
- The selected sensitivity range (low/medium or high) of the unit
- Diagnostic information: low battery, interference/wait, contaminated atmosphere readiness of the unit or fault conditions of the unit
- Keypad Controls:
- ON/OFF button (push-on/push-off)
- Volume/Mute button (high, low or mute)
- Sensitivity button for High, Medium and Low sensitivity level selection
- Peak button when multiple leaks are suspected (push enable/disable)
- Professional extruded aluminum block
- 2 1/2″ silicone dampened, recalibrateable gauges
- Free-floating piston type valves reduce o-ring wear
- Extra access port for vacuum line
- Extra large sight glass for visual refrigerant check
- Large easy-to-grip knobs
- R1234yf high and low side couplers with extended disconnect protection sleeve meets SAE J639 & J2888
- R134a high and low side manual couplers meet SAE, UL and EPA requirements for containment of refrigerant
- 1/2″ acme-m x 1/2″ acme-f LH thread adapter
- (2) 12 mm-m x 14 mm-F R1234yf adapters
- Set of 3 R134a standard hoses